Electric fireplace power requirements explained
Electric fireplace power requirements: watts, amps, the 15 A circuit, outlets, cords and when a hardwired or 240 V model needs an electrician.

Most plug-in electric fireplaces need a standard 120 V grounded outlet on a 15 A circuit, nothing more. On high the heater draws about 1,500 W, roughly 12 to 12.5 amps, which is about as much as one plug-in appliance should take from that circuit. So the real question is what else shares the circuit, and whether your model is a plug-in, a hardwired unit or a 240 V firebox.
Affiliate disclosureAs an Amazon Associate we earn from qualifying purchases made through links on this page. Commissions never change our ratings.
How many amps does an electric fireplace use?
Amps are watts divided by volts, so a 1,500 W heater on a 120 V outlet pulls 12.5 A. The manuals and maker pages we read land right there:
| Fireplace | Heater | Current | Connection |
|---|---|---|---|
| Touchstone Sideline 60" Smart | 750 / 1,500 W | 12 A max | plug-in or hardwired (manual) |
| Xbeauty 60" Recessed and Wall Mounted | 1,500 W | 12.5 A | plug-in, 120 V (listing) |
| Real Flame Crawford Slim 48" | 1,400 W | 12.6 A | three-prong outlet (maker page) |
| Dimplex BF45DXP built-in firebox | 1,440 W at 120 V, 2,700 W at 240 V | 12.0 A / 11.3 A | direct wire only (spec sheet) |
The flame on its own is a small load. Dimplex puts its flame effect at slightly under 300 W, so running the fire for looks in May barely registers. It's the heater that matters, and most heaters have a low step too: the Sideline runs at 750 W on its first setting.

Does an electric fireplace need a dedicated circuit?
Not by default, but it should not share one with much. The US electrical code (NEC 210.23(A)(1)) says a cord-and-plug appliance should not be rated above 80% of the branch circuit, which is 12 A on a 15 A circuit. A 1,500 W fireplace sits right on that line, so a space heater, a vacuum or a hair dryer on the same circuit is enough to trip the breaker.
The makers say the same thing in plain words. Touchstone's Sideline manual asks for a 120 V, 15 A grounded circuit, says to avoid plugging other appliances into it, and to unplug everything else if the fireplace trips the breaker. Dimplex says that if your lights dim when the unit runs, other appliances are on the circuit: try another outlet or have a dedicated 15 A breaker installed. The Westinghouse 60" listing goes as far as saying no other appliances on its 120 V, 15 A circuit.
Quick check before you buy: switch off the breaker that feeds the outlet you have in mind, walk around the house, and note what went dark. That list is what your fireplace will share.
- The TV-wall trap. The fireplace goes under the TV, so it gets plugged into the power strip with the TV, the soundbar and the console. That is the one place it must not go.
- The winter double. A portable space heater in the next room on the same circuit plus the fireplace on high is about 25 A on a 15 A breaker.
- The wrong box. A direct-wire firebox looks like a plug-in insert in photos. If the listing or spec sheet says hardwired, budget for an electrician.
The outlet, cords and power strips
- Wall outlet only. The CPSC, the U.S. Fire Administration and the Sideline manual all say the same: never an extension cord or a power strip. Touchstone adds surge protectors and relocatable power taps to the list.
- A tight fit. The plug should sit firmly in the outlet. If the plug, the outlet or the faceplate feels hot, stop using it and have an electrician look at the outlet (CPSC).
- Nothing else on that outlet. Consumer Reports advises against plugging another device into the same outlet as a heater.
- Timers and schedules. The manuals we read only mention the wall outlet. If you want the fire to switch off on its own, use the built-in timer: 0.5 to 8 hours on the Sideline, 10 minutes to 9 hours on the Crawford Slim.
No outlet where the fireplace should go? That is a job for a licensed electrician, and it is cheaper to plan before the wall is finished than after.

Hardwired and 240 V models are a different project
Some built-in fireboxes have no plug at all. The Dimplex BF45DXP is direct-wire only and can be connected at 240, 208 or 120 V. The voltage changes the heat: 2,700 W and about 9,200 BTU at 240 V, against 1,440 W and 5,000 BTU at 120 V. The Dimplex Revillusion firebox also changes with the supply: 1,300 W at 120 V, 2,575 W at 240 V. The Sideline can be plugged in or hardwired, as its manual explains.
Dimplex says plug-in fireplaces count as appliances and need no permit, while a hardwired built-in falls under your local building code, so check with the town or a licensed electrician. One more rule from the Revillusion guide: in a bathroom the unit must be protected by a GFCI outlet or circuit. We don't give wiring steps or breaker sizes here; the electrician signs for those.
Frequently asked questions
Do electric fireplaces need a dedicated circuit?
Plug-in models don’t require one, but they should not share a 15 A circuit with other big loads. A 1,500 W fireplace draws about 12.5 A, right at the 80% limit for a plug-in appliance on that circuit. If the breaker trips or the lights dim, Dimplex suggests another outlet or a dedicated 15 A breaker.
How many amps does an electric fireplace draw?
About 12 to 12.6 A on high for the 120 V models we rate: 12 A for the Touchstone Sideline, 12.5 A for the Xbeauty 60", 12.6 A for the Real Flame Crawford Slim. The flame alone uses far less.
Can I plug an electric fireplace into an extension cord or power strip?
No. The CPSC, the U.S. Fire Administration and the manuals we read all say to plug it straight into a wall outlet, never into an extension cord, power strip or surge protector.
Does a hardwired electric fireplace need an electrician?
Yes. Direct-wire and 240 V fireboxes such as the Dimplex BF45DXP are connected to the house wiring, which is work for a licensed electrician under your local code. Plug-in models need no permit, according to Dimplex.
Our rated picks
If you have a free 120 V outlet on a quiet circuit, every model in our built-in electric fireplace ranking works. The Touchstone Sideline 60" Smart (9.5/10) is the most flexible: plug-in today, hardwired later if you build it into a media wall. The Xbeauty 60" Recessed and Wall Mounted (9.3/10) is a straight plug-in at 12.5 A.
Want the classic look without touching the wiring? The Real Flame Crawford Slim 48" (9.2/10) plugs into a standard three-prong outlet and draws 1,400 W, a little less than the inserts. Planning a TV wall too? Our TV above an electric fireplace guide covers the second outlet, and what 1,500 watts covers shows what that power buys you in heat.



Product images: Amazon listings
Sources
- EC&M (Mike Holt Enterprises) — Code Q&A: Branch Circuit Requirements for Appliances (consulted Nov 2026)
- Touchstone Home Products (owner’s manual hosted by Wayfair) — Sideline Series Electric Fireplace Owner’s Manual (consulted Nov 2026)
- Dimplex (Glen Dimplex Americas) — Electric fireplace technical support (consulted Nov 2026)
- Dimplex (Glen Dimplex Americas) — Electric Fireplace FAQ (consulted Nov 2026)
- Dimplex (Glen Dimplex Americas) — BF45DXP Built-in Electric Firebox: Technical Specifications (consulted Nov 2026)
- Dimplex (Glen Dimplex Americas) — Revillusion Built-in Electric Firebox: Installation and User Guide (consulted Nov 2026)
- U.S. Consumer Product Safety Commission — Reducing Fire Hazards for Portable Electric Heaters (Publication 098) (consulted Nov 2026)
- U.S. Fire Administration — Heating Fire Safety (consulted Nov 2026)
- Consumer Reports — How to Use Your Space Heater Safely (consulted Nov 2026)
- Real Flame — Crawford Slim Electric Fireplace (consulted Nov 2026)